Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 2041 - 2055 of 2470 items found.

  • Contact Voltmeter

    CVM-780 - Prostat Corporation

    The CVM-780 Contact VoltmeterTM combines the ease of use of a digital voltmeter with the high input impedance and low input capacitance of a true electrostatic voltmeter in a small, portable, battery operated package.Being a true electrostatic voltmeter, not a field meter means that it reads real voltage, without confusing it with electrostatic field strength, which can be distinctly different.

  • Cable Test Van

    BAUR Transcable 4000/S 110-1 - BAUR Prüf- und Messtechnik GmbH

    Transcable 4000/S 110-1. The transcable 4000/S 110-1 cable test van is a 110 kV cable fault location system in single-phase version. The system is actuated with the semi-automatic MGS control unit. The high voltage switch unit is single-phase, up to 32 kV, the 110 kV switching level is designed as air-insulated ceiling switch.

  • Testing Services

    Computec SRL

    - Laboratory of electrical tests and measurements- Injection of voltages and currents. - Megger SMRT33 Triphasic Case- Protection relay test- Tests with class 0.2 instruments - Fluke N5K 3PP50IP Norma 5000 High Precision Power Analyzer- Verification of energy meters- Fault Recorder Verification- Verification of Power Quality Analyzers- GPS verification

  • OTP-Based Test System

    LXinstruments GmbH

    Power electronics assemblies often cannot be tested using conventional technology for their electrical performance. Due to the adaptability of the instrumentation, the OTP concept offers an ideal platform even beyond the space requirements of several control cabinets. In order to achieve high test flexibility with different assemblies, the system was equipped with three-phase AC sources and AC loads as well as a precise three-phase power meter. DC sources and loads with different current and voltage ranges cover the test of frequent DUT operating parameters. Time-dependent voltage or current signals can be stimulated by an arbitrary generator with power amplifier. General measurements such as current, voltage, frequency, resistance can be carried out flexibly at various test points using the matrix concept. An oscilloscope with RF multiplexer is available for high-frequency measurements such as residual ripple, switching processes, etc.

  • Analogue (1kV below) Insulation Tester

    1132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • DC Power Supply

    WPS Series - Matrix Technology Inc.

    The WPS Series programmable DC power supply is a high-precision, wide range of voltage & current within the power rating of the power supply, full-featured high power density programmable DC Power Supplies. It can provide wide-range, low-ripple and stable DC output which is used for DC input products and components function testing and experimental simulation.

  • Mini Digital Clamp Tester (CE)

    M-140HC - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *Easy!:Measurale Load Current at high voltage CV/CVT cables with grounding lines for shield phase.*Epoch-Making!:Can measure phase current of CVT cable just by putting CT head on to the conductors as well as CV cable just by clamping CT to the conductors in a lump.*Low Cost!:Can measure line/leakage current in the same manner as ordinary clamp meters.

  • LB-Series Digital AC Load Banks

    Eagle Eye Power Solutions

    The LB-Series AC Load Banks are designed for high power portable load testing of generators, UPS, and other critical AC power sources. Available models meet a range of voltages including but not limited to 208, 380, 440, and 480 VAC. Load power model options reach 1000 kW standard with other options available.

  • Primary Current Injection Test Trolley

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.

  • ±6 kV ANSI/ESDA/JEDEC HBM Test System

    HBM-TS10-A - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C

  • Adjustable High Frequency Reference Ballast

    HCS-109A - Lisun Electronics Inc.

    HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)

  • Rail Traction Inverter Test System

    Electromechanica, Inc.

    The rail inverter test system uses a pulse test methodology to verify proper operation of the IGBT switching elements in a subway car motor control. The system is designed to verify proper commutation of the switching elements. A large capacitor bank allows testing at DC voltages up to 1kV and peak currents of up to 3kA into reactive loads.The system also integrates self test capabilities and safe-to-turn-on (STTO) diagnostics to ensure no gross faults are present prior to the application of high voltages. Further the system includes dielectric withstand (hi-pot) test capability to ensure electrical safety.

  • Random Access Monochromator

    DeltaRAM X - HORIBA, Ltd.

    The patented DeltaRAM™ X microscope Illuminator is the ideal fluorescence illuminator for quantitative intracellular ion research. It utilizes a galvanometer-based Random Access Monochromator (RAM) that can switch between any wavelength in 2 milliseconds. The DeltaRAM™ X is a complete, self-contained, illuminator that includes a power supply, high intensity xenon light source, DeltaRAM™ X monochromator, TTL shutter and flexible liquid light guide. The wavelength position is a simple analog voltage control. All you need to add is a microscope adapter for your fluorescence microscope and a USB or PCI DAC interface depending on the software you will be using to drive the illuminator.

  • 2-in-1 High-Voltage Test Hood

    LX-HVE900EC - LXinstruments GmbH

    The test cells are made of stable, highly insulating plastic and are closed by a swiveling, transparent cover. The built-in safety switch is used to lock the hood and release the high-voltage sources. This ensures that no high voltage is active when the door is open. There is a generously dimensioned wiring space in the floor of the test cage. An interchangeable adapter plate in the test cell - optionally with an interchangeable interface or an interchangeable adapter cassette - allows quick adaptation to different types of test items. Prepared openings enable connectors and other common interfaces or cable bushings to be easily attached. The hood is opened and closed almost effortlessly thanks to precisely coordinated gas springs.

  • Analyzers and Timers

    CAT Advanced Series - Amperis sl

    Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:

Get Help